Customizing Your OTDR
OTDR 93
Selecting the Distance Units
Selecting the Distance Units
You can select the measurement units that will be used throughout the
application, except for certain values such as the pulse and the
wavelength. Pulse values are expressed in seconds and wavelength in
meters (nanometers).
The default distance units are the kilometers.
Note: If you select Kilometers (km) or Kilofeet (kft), m and ft may appear
instead to display more precise measurements.
Note: The distance units used in Auto, Advanced, and Template modes are
independent from the ones used in the Fault Finder mode.
Note: The attenuation of fiber sections is always presented in dBs per kilometer
even if the distance units you selected are not the kilometers. This follows
the standards of the fiber-optic industry that provides the attenuation
values in dBs per kilometer.