Noise Tests
238 FTB-610
VF Noise Test
Setting Threshold Values
The Test Thresholds page allows you to set the VF Noise Threshold
values for the test.
To set the Threshold values:
1. From the Copper main menu Test Groups, select Noise test
.
2. From the Tests menu, select VF Noise test.
3. Tap Continuous tab.
4. Tap Edit Thresholds button to open the Test Thresholds page.
5. Set the Threshold values as required.
6. Tap Close to confirm and exit the page.
The page allows you to set the following parameters:
Threshold is the threshold limit for each pair: Maximum, Minimum, or
None.
Threshold Noise sets the threshold value.