Optimizing Measurements
132 FTB-5600
Use an Appropriate Spatial Smoothing Filter Value
Below is an example of applying different filter values to a same trace. The
first curve has a filter of 100 m applied to it. The noise is quite visible and
the PMD changes are sharp. Attempting to take measurements on this
trace without a filter is not recommended, as there is too much noise.