Exfo FTB-3930 MultiTest Manuale Utente Pagina 29

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 28
Measuring Power or Loss
Multifunction Loss Tester 23
Referencing Your Power Meter to a Source
Referencing Your Power Meter to a Source
In reference mode, your unit displays the loss created by the fiber under
test only, since it subtracts a reference value from the measured power.
In the illustration, the reference value (-2.62 dBm) is subtracted from the
actual power measured (-2.465 dBm).
Note: The reference value you set for each wavelength remains in memory until a
new one is set for the same wavelength, even when you turn the unit off.
Reference
power
Measured loss
Vedere la pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 100 101

Commenti su questo manuale

Nessun commento